Degson Inductive proximity sensors

68 Degson part numbers. Copy the one you need or request a quote.

Request a quote

Every description in this list includes Inductive proximity sensor, Indicator lights: Operating status: LED, Output mode: NPN.

  • DLE-N08-2.5NC
    This part
    • Installation method: Non-flush
    • Detection distance: 2.5mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLE-N08-2.5NO
    This part
    • Installation method: Non-flush
    • Detection distance: 2.5mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLE-N09-2.5NC
    This part
    • Installation method: Non-flush
    • Detection distance: 2.5mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLE-N09-2.5NO
    This part
    • Installation method: Non-flush
    • Detection distance: 2.5mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLE-N10-2.5NC
    This part
    • Installation method: Non-flush
    • Detection distance: 2.5mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLE-N10-2.5NO
    This part
    • Installation method: Non-flush
    • Detection distance: 2.5mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLE-N12-04NC
    This part
    • Installation method: Non-flush
    • Detection distance: 4.0mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLE-N12-04NO
    This part
    • Installation method: Non-flush
    • Detection distance: 4.0mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLL-F08-02NC
    This part
    • Installation method: Flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-F08-02NO
    This part
    • Installation method: Flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-F12-04NC
    This part
    • Installation method: Flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-F12-04NO
    This part
    • Installation method: Flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-F18-08NC
    This part
    • Installation method: Flush
    • Detection distance: 8.0mm±10%
    • Thread specifications: M18
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-F18-08NO
    This part
    • Installation method: Flush
    • Detection distance: 8.0mm±10%
    • Thread specifications: M18
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-N08-04NC
    This part
    • Installation method: Non-flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤20mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-N08-04NO
    This part
    • Installation method: Non-flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤20mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-N12-08NC
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLL-N12-08NO
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLQ-F17-05NC
    This part
    • Installation method: Flush
    • Detection distance: 5.0mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-F17-05NO
    This part
    • Installation method: Flush
    • Detection distance: 5.0mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-F18-05NC
    This part
    • Installation method: Flush
    • Detection distance: 5.0mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-F18-05NO
    This part
    • Installation method: Flush
    • Detection distance: 5.0mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-F18C-05NC
    This part
    • Installation method: Flush
    • Detection distance: 5.0mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-F18C-05NO
    This part
    • Installation method: Flush
    • Detection distance: 5.0mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-N17-08NC
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-N17-08NO
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-N18-08NC
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-N18-08NO
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-N18C-08NC
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLQ-N18C-08NO
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLR-F08-1.5NC
    This part
    • Installation method: Flush
    • Detection distance: 1.5mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-F08-1.5NO
    This part
    • Installation method: Flush
    • Detection distance: 1.5mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-F12-02NC
    This part
    • Installation method: Flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-F12-02NO
    This part
    • Installation method: Flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-F18-05NC
    This part
    • Installation method: Flush
    • Detection distance: 5.0mm±10%
    • Thread specifications: M18
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-F18-05NO
    This part
    • Installation method: Flush
    • Detection distance: 5.0mm±10%
    • Thread specifications: M18
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-N08-02NC
    This part
    • Installation method: Non-flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-N08-02NO
    This part
    • Installation method: Non-flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-N12-04NC
    This part
    • Installation method: Non-flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-N12-04NO
    This part
    • Installation method: Non-flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-N18-08NC
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Thread specifications: M18
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤20mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLR-N18-08NO
    This part
    • Installation method: Non-flush
    • Detection distance: 8.0mm±10%
    • Thread specifications: M18
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤20mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLS-F08-02NC
    This part
    • Installation method: Flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLS-F08-02NO
    This part
    • Installation method: Flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLS-F12-04NC
    This part
    • Installation method: Flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLS-F12-04NO
    This part
    • Installation method: Flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLS-N08-04NC
    This part
    • Installation method: Non-flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLS-N08-04NO
    This part
    • Installation method: Non-flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLSS-F08-02NC
    This part
    • Installation method: Flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLSS-F08-02NO
    This part
    • Installation method: Flush
    • Detection distance: 2.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLSS-F12-04NC
    This part
    • Installation method: Flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLSS-F12-04NO
    This part
    • Installation method: Flush
    • Detection distance: 4.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLX-F03-0.8NC
    This part
    • Installation method: Flush
    • Detection distance: 0.8mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 100mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLX-F03-0.8NO
    This part
    • Installation method: Flush
    • Detection distance: 0.8mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 100mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLX-F04-1.2NC
    This part
    • Installation method: Flush
    • Detection distance: 1.2mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLX-F04-1.2NO
    This part
    • Installation method: Flush
    • Detection distance: 1.2mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLX-F04-1.5NC
    This part
    • Installation method: Flush
    • Detection distance: 1.5mm±10%
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLX-F04-1.5NO
    This part
    • Installation method: Flush
    • Detection distance: 1.5mm±10%
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
    • Insulation resistance: ≥50MΩ (500VDC) between the power supply terminals and the casing
  • DLX-F05-1.5NC
    This part
    • Installation method: Flush
    • Detection distance: 1.5mm±10%
    • Thread specifications: M5
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLX-F05-1.5NO
    This part
    • Installation method: Flush
    • Detection distance: 1.5mm±10%
    • Thread specifications: M5
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLY-F08-03NC
    This part
    • Installation method: Flush
    • Detection distance: 3.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLY-F08-03NO
    This part
    • Installation method: Flush
    • Detection distance: 3.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLY-F12-06NC
    This part
    • Installation method: Flush
    • Detection distance: 6.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLY-F12-06NO
    This part
    • Installation method: Flush
    • Detection distance: 6.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤2.0V
    • Load current: 150mA
  • DLY-N08-06NC
    This part
    • Installation method: Non-flush
    • Detection distance: 6.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLY-N08-06NO
    This part
    • Installation method: Non-flush
    • Detection distance: 6.0mm±10%
    • Thread specifications: M8
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLY-N12-10NC
    This part
    • Installation method: Non-flush
    • Detection distance: 10.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally closed
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA
  • DLY-N12-10NO
    This part
    • Installation method: Non-flush
    • Detection distance: 10.0mm±10%
    • Thread specifications: M12
    • Switch mode: Normally open
    • Operating voltage: 10~30V DC±10%
    • Consume current: ≤10mA
    • Residual voltage: ≤1.5V
    • Load current: 150mA

Descriptions come from our catalog. Check the datasheet, or ask us, before you order.